{"product_id":"cnc-ycqr-63-4p-3-phase-63a-dual-power-automatic-transfer-switch-ats","title":"CNC YCQR-63 4P 3 Phase 63A Dual Power Automatic Transfer Switch ATS","description":"\u003cdiv class=\"soltrix-description-reference\" style='font-family:\"DM Sans\",Arial,sans-serif;font-size:14px;line-height:24px;color:#3c3c3c;letter-spacing:0;text-align:left;overflow-wrap:anywhere;'\u003e\n\u003ch3 style=\"font-size:14px;line-height:24px;font-weight:700;color:#232323;margin:20px 0 10px;\"\u003e\u003cstrong style=\"font-size:inherit;line-height:inherit;font-weight:700;color:inherit;\"\u003eCNC YCQR-63 4P 3 Phase 63A Dual Power Automatic Transfer Switch ATS\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp style=\"font-size:14px;line-height:24px;color:#3c3c3c;margin:0 0 17px;\"\u003eThe \u003cstrong style=\"font-size:inherit;line-height:inherit;font-weight:700;color:inherit;\"\u003eCNC YCQR-63 4P\u003c\/strong\u003e is a high-quality \u003cstrong style=\"font-size:inherit;line-height:inherit;font-weight:700;color:inherit;\"\u003e3-phase dual power automatic transfer switch\u003c\/strong\u003e (ATS) designed to provide reliable and seamless switching between power sources. With its advanced features, it ensures a continuous power supply to critical electrical systems while offering protection and convenience for both residential and commercial applications.\u003c\/p\u003e\n\u003cp style=\"font-size:14px;line-height:24px;color:#3c3c3c;margin:0 0 17px;\"\u003e\u003cstrong style=\"font-size:inherit;line-height:inherit;font-weight:700;color:inherit;\"\u003eKey Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"font-size:14px;line-height:24px;margin:18px 0 10px 17px;padding:0 0 22px;list-style-position:outside;list-style-type:disc;\"\u003e\n\u003cli style=\"font-size:14px;line-height:24px;margin:0 0 10px;padding:0;display:list-item;\"\u003e\n\u003cstrong style=\"font-size:inherit;line-height:inherit;font-weight:700;color:inherit;\"\u003eRated Insulation\nVoltage\u003c\/strong\u003e: 690V, ensuring safe and efficient operation in a variety of settings.\u003c\/li\u003e\n\u003cli style=\"font-size:14px;line-height:24px;margin:0 0 10px;padding:0;display:list-item;\"\u003e\n\u003cstrong style=\"font-size:inherit;line-height:inherit;font-weight:700;color:inherit;\"\u003eRated Working\nVoltage\u003c\/strong\u003e: AC440V, compatible with most industrial electrical systems.\u003c\/li\u003e\n\u003cli style=\"font-size:14px;line-height:24px;margin:0 0 10px;padding:0;display:list-item;\"\u003e\n\u003cstrong style=\"font-size:inherit;line-height:inherit;font-weight:700;color:inherit;\"\u003eShort Circuit\nProtection\u003c\/strong\u003e: 50kA short-circuit current rating for enhanced safety.\u003c\/li\u003e\n\u003cli style=\"font-size:14px;line-height:24px;margin:0 0 10px;padding:0;display:list-item;\"\u003e\n\u003cstrong style=\"font-size:inherit;line-height:inherit;font-weight:700;color:inherit;\"\u003ePoles\u003c\/strong\u003e : 4P, suitable for 3-phase systems with neutral.\u003c\/li\u003e\n\u003cli style=\"font-size:14px;line-height:24px;margin:0 0 10px;padding:0;display:list-item;\"\u003e\n\u003cstrong style=\"font-size:inherit;line-height:inherit;font-weight:700;color:inherit;\"\u003eControl Circuit\nVoltage\u003c\/strong\u003e: AC220V, 50Hz, for stable and reliable control.\u003c\/li\u003e\n\u003cli style=\"font-size:14px;line-height:24px;margin:0 0 10px;padding:0;display:list-item;\"\u003e\n\u003cstrong style=\"font-size:inherit;line-height:inherit;font-weight:700;color:inherit;\"\u003eFast Switching Time\u003c\/strong\u003e : Contactor changeover time of less than 50ms, ensuring minimal downtime during transfer.\u003c\/li\u003e\n\u003cli style=\"font-size:14px;line-height:24px;margin:0 0 10px;padding:0;display:list-item;\"\u003e\n\u003cstrong style=\"font-size:inherit;line-height:inherit;font-weight:700;color:inherit;\"\u003eAuxiliary Circuit\u003c\/strong\u003e : AC220V, 50Hz, with 5A capacity for additional load connections.\u003c\/li\u003e\n\u003cli style=\"font-size:14px;line-height:24px;margin:0 0 10px;padding:0;display:list-item;\"\u003e\n\u003cstrong style=\"font-size:inherit;line-height:inherit;font-weight:700;color:inherit;\"\u003eDurability\u003c\/strong\u003e : Built to withstand tough working conditions with high impulse withstand voltage of 8kV.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size:14px;line-height:24px;color:#3c3c3c;margin:0 0 17px;\"\u003e\u003cstrong style=\"font-size:inherit;line-height:inherit;font-weight:700;color:inherit;\"\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul style=\"font-size:14px;line-height:24px;margin:18px 0 10px 17px;padding:0 0 22px;list-style-position:outside;list-style-type:disc;\"\u003e\n\u003cli style=\"font-size:14px;line-height:24px;margin:0 0 10px;padding:0;display:list-item;\"\u003e\n\u003cstrong style=\"font-size:inherit;line-height:inherit;font-weight:700;color:inherit;\"\u003eRated Operating Current (Ie)\u003c\/strong\u003e : 63A\u003c\/li\u003e\n\u003cli style=\"font-size:14px;line-height:24px;margin:0 0 10px;padding:0;display:list-item;\"\u003e\n\u003cstrong style=\"font-size:inherit;line-height:inherit;font-weight:700;color:inherit;\"\u003eRated Insulation Voltage (Ui)\u003c\/strong\u003e : 690V\u003c\/li\u003e\n\u003cli style=\"font-size:14px;line-height:24px;margin:0 0 10px;padding:0;display:list-item;\"\u003e\n\u003cstrong style=\"font-size:inherit;line-height:inherit;font-weight:700;color:inherit;\"\u003eRated Impulse Withstand Voltage (Uimp)\u003c\/strong\u003e : 8kV\u003c\/li\u003e\n\u003cli style=\"font-size:14px;line-height:24px;margin:0 0 10px;padding:0;display:list-item;\"\u003e\n\u003cstrong style=\"font-size:inherit;line-height:inherit;font-weight:700;color:inherit;\"\u003eRated Working Voltage (Ue)\u003c\/strong\u003e : AC440V\u003c\/li\u003e\n\u003cli style=\"font-size:14px;line-height:24px;margin:0 0 10px;padding:0;display:list-item;\"\u003e\n\u003cstrong style=\"font-size:inherit;line-height:inherit;font-weight:700;color:inherit;\"\u003eRated\nFrequency\u003c\/strong\u003e: 50\/60Hz\u003c\/li\u003e\n\u003cli style=\"font-size:14px;line-height:24px;margin:0 0 10px;padding:0;display:list-item;\"\u003e\n\u003cstrong style=\"font-size:inherit;line-height:inherit;font-weight:700;color:inherit;\"\u003ePole Number\u003c\/strong\u003e : 4P (for 3-phase systems with neutral)\u003c\/li\u003e\n\u003cli style=\"font-size:14px;line-height:24px;margin:0 0 10px;padding:0;display:list-item;\"\u003e\n\u003cstrong style=\"font-size:inherit;line-height:inherit;font-weight:700;color:inherit;\"\u003eRated Short-Circuit Current (Iq)\u003c\/strong\u003e : 50kA\u003c\/li\u003e\n\u003cli style=\"font-size:14px;line-height:24px;margin:0 0 10px;padding:0;display:list-item;\"\u003e\n\u003cstrong style=\"font-size:inherit;line-height:inherit;font-weight:700;color:inherit;\"\u003eShort Circuit Protection Device (Fuse)\u003c\/strong\u003e : RT16-00-63A\u003c\/li\u003e\n\u003cli style=\"font-size:14px;line-height:24px;margin:0 0 10px;padding:0;display:list-item;\"\u003e\n\u003cstrong style=\"font-size:inherit;line-height:inherit;font-weight:700;color:inherit;\"\u003eControl Circuit\u003c\/strong\u003e : AC220V, 50Hz\u003c\/li\u003e\n\u003cli style=\"font-size:14px;line-height:24px;margin:0 0 10px;padding:0;display:list-item;\"\u003e\n\u003cstrong style=\"font-size:inherit;line-height:inherit;font-weight:700;color:inherit;\"\u003eNormal Working Conditions\u003c\/strong\u003e : 85%Us to 110%Us\u003c\/li\u003e\n\u003cli style=\"font-size:14px;line-height:24px;margin:0 0 10px;padding:0;display:list-item;\"\u003e\n\u003cstrong style=\"font-size:inherit;line-height:inherit;font-weight:700;color:inherit;\"\u003eAuxiliary Circuit\u003c\/strong\u003e : AC220V, 50Hz, with 5A capacity\u003c\/li\u003e\n\u003cli style=\"font-size:14px;line-height:24px;margin:0 0 10px;padding:0;display:list-item;\"\u003e\n\u003cstrong style=\"font-size:inherit;line-height:inherit;font-weight:700;color:inherit;\"\u003eContactor Changeover Time\u003c\/strong\u003e : \u0026lt;50ms\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size:14px;line-height:24px;color:#3c3c3c;margin:0 0 17px;\"\u003eThe \u003cstrong style=\"font-size:inherit;line-height:inherit;font-weight:700;color:inherit;\"\u003eCNC YCQR-63 4P ATS\u003c\/strong\u003e ensures a fast, safe, and efficient power transfer for industrial and commercial systems, with robust short-circuit protection and a quick switching mechanism, making it ideal for applications requiring uninterrupted power.\u003c\/p\u003e\n\u003cdiv style=\"width:100%;max-width:100%;overflow-x:auto;-webkit-overflow-scrolling:touch;\"\u003e\u003ctable style=\"width:100%;max-width:100%;border-collapse:collapse;border-spacing:0;table-layout:auto;font-size:14px;line-height:24px;border:0;margin:0;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color:#f1f1f1;border:0;\"\u003e\n\u003ctd style=\"font-size:14px;line-height:24px;color:#3c3c3c;padding:11px 13px 8px;border:0;vertical-align:top;background-color:#f1f1f1;text-align:left;font-weight:400;overflow-wrap:anywhere;width:52.1337%;\"\u003eCase grade\u003c\/td\u003e\n\u003ctd style=\"font-size:14px;line-height:24px;color:#3c3c3c;padding:11px 13px 8px;border:0;vertical-align:top;background-color:#f1f1f1;text-align:left;font-weight:400;overflow-wrap:anywhere;width:47.6239%;\"\u003e63\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color:#ffffff;border:0;\"\u003e\n\u003ctd style=\"font-size:14px;line-height:24px;color:#3c3c3c;padding:11px 13px 8px;border:0;vertical-align:top;background-color:#ffffff;text-align:left;font-weight:400;overflow-wrap:anywhere;width:52.1337%;\"\u003eRated operating curent le(A)\u003c\/td\u003e\n\u003ctd style=\"font-size:14px;line-height:24px;color:#3c3c3c;padding:11px 13px 8px;border:0;vertical-align:top;background-color:#ffffff;text-align:left;font-weight:400;overflow-wrap:anywhere;width:47.6239%;\"\u003e63A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color:#f1f1f1;border:0;\"\u003e\n\u003ctd style=\"font-size:14px;line-height:24px;color:#3c3c3c;padding:11px 13px 8px;border:0;vertical-align:top;background-color:#f1f1f1;text-align:left;font-weight:400;overflow-wrap:anywhere;width:52.1337%;\"\u003eRated insulation voltage Ul\u003c\/td\u003e\n\u003ctd style=\"font-size:14px;line-height:24px;color:#3c3c3c;padding:11px 13px 8px;border:0;vertical-align:top;background-color:#f1f1f1;text-align:left;font-weight:400;overflow-wrap:anywhere;width:47.6239%;\"\u003e690V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color:#ffffff;border:0;\"\u003e\n\u003ctd style=\"font-size:14px;line-height:24px;color:#3c3c3c;padding:11px 13px 8px;border:0;vertical-align:top;background-color:#ffffff;text-align:left;font-weight:400;overflow-wrap:anywhere;width:52.1337%;\"\u003eRated impulse withstand voltage Uimp\u003c\/td\u003e\n\u003ctd style=\"font-size:14px;line-height:24px;color:#3c3c3c;padding:11px 13px 8px;border:0;vertical-align:top;background-color:#ffffff;text-align:left;font-weight:400;overflow-wrap:anywhere;width:47.6239%;\"\u003e8kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color:#f1f1f1;border:0;\"\u003e\n\u003ctd style=\"font-size:14px;line-height:24px;color:#3c3c3c;padding:11px 13px 8px;border:0;vertical-align:top;background-color:#f1f1f1;text-align:left;font-weight:400;overflow-wrap:anywhere;width:52.1337%;\"\u003eRated working voltage Ue\u003c\/td\u003e\n\u003ctd style=\"font-size:14px;line-height:24px;color:#3c3c3c;padding:11px 13px 8px;border:0;vertical-align:top;background-color:#f1f1f1;text-align:left;font-weight:400;overflow-wrap:anywhere;width:47.6239%;\"\u003eAC440V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color:#ffffff;border:0;\"\u003e\n\u003ctd style=\"font-size:14px;line-height:24px;color:#3c3c3c;padding:11px 13px 8px;border:0;vertical-align:top;background-color:#ffffff;text-align:left;font-weight:400;overflow-wrap:anywhere;width:52.1337%;\"\u003eRated frequency\u003c\/td\u003e\n\u003ctd style=\"font-size:14px;line-height:24px;color:#3c3c3c;padding:11px 13px 8px;border:0;vertical-align:top;background-color:#ffffff;text-align:left;font-weight:400;overflow-wrap:anywhere;width:47.6239%;\"\u003e50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color:#f1f1f1;border:0;\"\u003e\n\u003ctd style=\"font-size:14px;line-height:24px;color:#3c3c3c;padding:11px 13px 8px;border:0;vertical-align:top;background-color:#f1f1f1;text-align:left;font-weight:400;overflow-wrap:anywhere;width:52.1337%;\"\u003eClass\u003c\/td\u003e\n\u003ctd style=\"font-size:14px;line-height:24px;color:#3c3c3c;padding:11px 13px 8px;border:0;vertical-align:top;background-color:#f1f1f1;text-align:left;font-weight:400;overflow-wrap:anywhere;width:47.6239%;\"\u003ePC class: can be switched on and loaded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color:#ffffff;border:0;\"\u003e\n\u003ctd style=\"font-size:14px;line-height:24px;color:#3c3c3c;padding:11px 13px 8px;border:0;vertical-align:top;background-color:#ffffff;text-align:left;font-weight:400;overflow-wrap:anywhere;width:52.1337%;\"\u003ewithout generating short-circuit current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color:#f1f1f1;border:0;\"\u003e\n\u003ctd style=\"font-size:14px;line-height:24px;color:#3c3c3c;padding:11px 13px 8px;border:0;vertical-align:top;background-color:#f1f1f1;text-align:left;font-weight:400;overflow-wrap:anywhere;width:52.1337%;\"\u003ePolenumber\u003c\/td\u003e\n\u003ctd style=\"font-size:14px;line-height:24px;color:#3c3c3c;padding:11px 13px 8px;border:0;vertical-align:top;background-color:#f1f1f1;text-align:left;font-weight:400;overflow-wrap:anywhere;width:47.6239%;\"\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color:#ffffff;border:0;\"\u003e\n\u003ctd style=\"font-size:14px;line-height:24px;color:#3c3c3c;padding:11px 13px 8px;border:0;vertical-align:top;background-color:#ffffff;text-align:left;font-weight:400;overflow-wrap:anywhere;width:52.1337%;\"\u003eRated short-circuit current Iq\u003c\/td\u003e\n\u003ctd style=\"font-size:14px;line-height:24px;color:#3c3c3c;padding:11px 13px 8px;border:0;vertical-align:top;background-color:#ffffff;text-align:left;font-weight:400;overflow-wrap:anywhere;width:47.6239%;\"\u003e50kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color:#f1f1f1;border:0;\"\u003e\n\u003ctd style=\"font-size:14px;line-height:24px;color:#3c3c3c;padding:11px 13px 8px;border:0;vertical-align:top;background-color:#f1f1f1;text-align:left;font-weight:400;overflow-wrap:anywhere;width:52.1337%;\"\u003eShort circuit protection device (fuse)\u003c\/td\u003e\n\u003ctd style=\"font-size:14px;line-height:24px;color:#3c3c3c;padding:11px 13px 8px;border:0;vertical-align:top;background-color:#f1f1f1;text-align:left;font-weight:400;overflow-wrap:anywhere;width:47.6239%;\"\u003eRT16-00-63A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color:#ffffff;border:0;\"\u003e\n\u003ctd style=\"font-size:14px;line-height:24px;color:#3c3c3c;padding:11px 13px 8px;border:0;vertical-align:top;background-color:#ffffff;text-align:left;font-weight:400;overflow-wrap:anywhere;width:52.1337%;\"\u003eRated impulse withstand voltage\u003c\/td\u003e\n\u003ctd style=\"font-size:14px;line-height:24px;color:#3c3c3c;padding:11px 13px 8px;border:0;vertical-align:top;background-color:#ffffff;text-align:left;font-weight:400;overflow-wrap:anywhere;width:47.6239%;\"\u003e8kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color:#f1f1f1;border:0;\"\u003e\n\u003ctd style=\"font-size:14px;line-height:24px;color:#3c3c3c;padding:11px 13px 8px;border:0;vertical-align:top;background-color:#f1f1f1;text-align:left;font-weight:400;overflow-wrap:anywhere;width:52.1337%;\"\u003eControl circuit\u003c\/td\u003e\n\u003ctd style=\"font-size:14px;line-height:24px;color:#3c3c3c;padding:11px 13px 8px;border:0;vertical-align:top;background-color:#f1f1f1;text-align:left;font-weight:400;overflow-wrap:anywhere;width:47.6239%;\"\u003eRated control voltage Us: AC220V,50Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color:#ffffff;border:0;\"\u003e\n\u003ctd style=\"font-size:14px;line-height:24px;color:#3c3c3c;padding:11px 13px 8px;border:0;vertical-align:top;background-color:#ffffff;text-align:left;font-weight:400;overflow-wrap:anywhere;width:52.1337%;\"\u003eNormal working conditions: 85%Us-110%Us\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color:#f1f1f1;border:0;\"\u003e\n\u003ctd style=\"font-size:14px;line-height:24px;color:#3c3c3c;padding:11px 13px 8px;border:0;vertical-align:top;background-color:#f1f1f1;text-align:left;font-weight:400;overflow-wrap:anywhere;width:52.1337%;\"\u003eAuxiliary circuit\u003c\/td\u003e\n\u003ctd style=\"font-size:14px;line-height:24px;color:#3c3c3c;padding:11px 13px 8px;border:0;vertical-align:top;background-color:#f1f1f1;text-align:left;font-weight:400;overflow-wrap:anywhere;width:47.6239%;\"\u003eAC220V 50Hzle=5A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color:#ffffff;border:0;\"\u003e\n\u003ctd style=\"font-size:14px;line-height:24px;color:#3c3c3c;padding:11px 13px 8px;border:0;vertical-align:top;background-color:#ffffff;text-align:left;font-weight:400;overflow-wrap:anywhere;width:52.1337%;\"\u003eContactor change-overtime\u003c\/td\u003e\n\u003ctd style=\"font-size:14px;line-height:24px;color:#3c3c3c;padding:11px 13px 8px;border:0;vertical-align:top;background-color:#ffffff;text-align:left;font-weight:400;overflow-wrap:anywhere;width:47.6239%;\"\u003e\u0026lt;50ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:14px;line-height:24px;color:#3c3c3c;margin:0 0 17px;\"\u003eRated Operating.\n\nCurrent: 63A, designed for high-power applications.\u003c\/p\u003e\n\u003cp style=\"font-size:14px;line-height:24px;color:#3c3c3c;margin:0 0 17px;\"\u003eSpecifications\u003c\/p\u003e\n\u003c\/div\u003e","brand":"SOLTRIX ENERGY","offers":[{"title":"Default Title","offer_id":52378426245336,"sku":"SLX-CHG-0654","price":9350.0,"currency_code":"PKR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0837\/7928\/9304\/files\/CNC_YCQR-63_4P_3_Phase_63A_Dual_Power_Automatic_Transfer_Switch_ATS.png?v=1791490642","url":"https:\/\/soltrixenergy.pk\/products\/cnc-ycqr-63-4p-3-phase-63a-dual-power-automatic-transfer-switch-ats","provider":"SOLTRIX ENERGY","version":"1.0","type":"link"}